Client portal

Client Portal

Sites, equipment, HACCP data, service tickets and documents in one place. Without logging in you see the demo access with sample data.

Login

Demo access – no physical equipment is controlled, all values are sample data. Customers log in with their credentials via “Login”.

Client Portal Riverside DC GmbH · demo access

Demo data Max Mustermann

Overview

  • Sites3
  • Equipment14
  • Open service tickets3
  • HACCP status8/8 in range
  • Active alerts1
  • Next service visit 09:30

Current project — AHU upgrade

  1. Assessment
  2. Engineering
  3. Installation
  4. Commissioning

Anomaly detected

Refrigeration unit 01 — increased condensing temperature.The model detects a trend indicating condenser contamination.
The service visit is scheduled.

Go to trends

Latest documents

Latest service event

  • Maintenance AHU 02 completed8 Sep 2026 · technician · report filed
  • Service visit scheduled: refrigeration unit 01

Sites

3 sites · 14 systems

SiteCityEquipmentOpen ticketsHACCPStatus
Central warehouse NorthFrankfurt am Main614/4 in rangeRunning
Production SouthGiessen523/3 in rangeAlert active
Admin & server roomHanau301/1 in rangeRunning

Each site leads to its equipment, HACCP rooms, tickets and documents — addresses are deliberately left out of the demo access.

Equipment

7 of 14 systems shown

IDSystemSiteTypeStatusNext service
EQ-00131Refrigeration unit 01Production SouthRefrigeration systemWarning
EQ-00127Cold room 04Central warehouse NorthCold roomActive
EQ-00114Booster rackCentral warehouse NorthRefrigeration rackActive
EQ-00076AHU 02Production SouthVentilationActive8 Mar 2027
EQ-00142Ventilation unit L1Central warehouse NorthVentilationActive
EQ-00150Split AC server roomAdmin & server roomAir conditioningActive
EQ-00098Production refrigeration plantProduction SouthRefrigeration systemActive

Every system carries documents, service history and its next due date — reminders go to the assigned roles before the date.

HACCP monitoring

Temperature history · events · export

  1. Client portal
  2. Site
  3. Equipment
  4. HACCP
  5. Temperature history
  6. Events
  7. Export
Site: Central warehouse NorthEquipment: Cold room 02Period: 31 Aug 2026

Cold Room 02 Normal

Temperature history · 31 Aug 2026, 00:00 – 23:59

  • Temperature (°C)
  • Upper limit (4.0 °C)
  • Lower limit (−2.5 °C)
  • Door opening
  • Defrost
  • Deviation
  • Normal range
  • Current−1.7 °C
  • Minimum−2.3 °C at 08:19
  • Maximum4.3 °C at 05:59
  • Average−1.4 °C
  • Time in range99.6%
  • Deviations1 6 min

Events (24 h)

  • Door openings32
  • Total door-open time56 min
  • Defrosts (planned)4
  • Temperature deviations1
  • Total deviation time6 min

Compressor run time

  • Total run time10 h 41 min
  • Starts36
  • Longest run1 h 25 min
  • Total stop time13 h 19 min

Sensor & system

  • Sensor statusHealthy
  • Calibration due12 Nov 2026
  • Battery level100%
  • Signal strengthExcellent

Tamper-proof storage: append-only, redundant, with checksums – designed for the strictest retention period the food-safety authority is likely to require.

Events · 31 Aug 2026

TimeEventValueDuration
03:00Defrost 1 of 4 (planned)peak 2.0 °C12 min
05:31Delivery: door opened 5× (05:31–06:12), longest opening 14 min—31 min
05:36Door open longer than 5 min – alarm (delivery), acknowledged 05:38 (M. Weber)—5 min 30 s
05:50Door open longer than 5 min – alarm (delivery), acknowledged 05:52 (M. Weber)—14 min
05:57Upper limit 4.0 °C exceeded – alarm sent to shift supervisor4.1 °C6 min
05:59Peak of the deviation4.3 °C—
06:03Back in range (deviation 6 min)4.0 °C—
06:05Alarm acknowledged, corrective action documented (M. Weber, shift supervisor)——
08:00–20:00Daytime door openings: 27× (20 s – 3 min each)—25 min
09:00Defrost 2 of 4 (planned)peak 2.2 °C16 min
15:00Defrost 3 of 4 (planned)peak 1.6 °C13 min
21:00Defrost 4 of 4 (planned)peak 2.5 °C14 min
1 Sep · 00:05Daily report created (PDF/Excel)——

Alerts

1 active · 2 acknowledged · 1 resolved

  • Active
    Refrigeration unit 01 — increased condensing temperature.

    The model detects a trend indicating condenser contamination. The service visit is scheduled.

    Source: anomaly model · action: service visit · ticket TK-2026-158

  • Acknowledged
    Cold room 02 — door open longer than 5 minutes

    Acknowledged by site management · temperature stayed in range

  • Acknowledged
    Cold room 02 — door open longer than 5 min (delivery, 2×)

    Alarms at 05:36 and 05:50 · acknowledged by M. Weber, shift supervisor

  • Resolved
    Cold room 02 — temperature deviation up to 4.3 °C (6 min)

    Back in range at 06:03 · acknowledged by M. Weber, shift supervisor · documented in the HACCP report

Acknowledging — what it means

  • By acknowledging, an authorised person confirms that they have seen the alarm and are taking care of it. Name and time are recorded in the activity log; the alarm stays visible until the cause is fixed.
  • If the building management system is connected (e.g. Siemens Desigo CC via BACnet), the acknowledgement is passed back to the plant – where the interface allows it in the project. In the demo access the button only changes the display.

Alert rules

  • Limit exceeded — upper and lower limit per cold room
  • Door open longer than 5 minutes
  • Sensor failure or signal loss
  • Anomaly model — trend deviation from normal operation
  • Escalation via portal notification and e-mail

Service tickets

3 open

  • 3Open
  • 1In progress
  • 1Scheduled
  • 6Closed (30 days)
  • High
    TK-2026-158Refrigeration unit 01 — condensing temperature increased · scheduled
  • Medium
    TK-2026-155Door contact switch faulty · Central warehouse North · in progress
  • Low
    TK-2026-153Door alignment cold room 03 · received
  1. Received
  2. Assessed
  3. Scheduled
  4. In progress
  5. Closed

How the priority is set

  • You report a ticket in the portal and choose the impact on your operation: goods or operation at risk · function restricted · no impact on operation. This gives the proposal High, Medium or Low.
  • Tickets the system creates itself (alarm, anomaly model) take their priority from the alert rule – a HACCP limit violation, for example, is always High.
  • JuKo Tech reviews every ticket in the “Assessed” step and sets the binding priority. It determines the response time under the maintenance contract; any change is noted in the ticket with a reason.

Documents

6 documents · versioned

DocumentCategoryDateStatus
Proposal_2041.pdfProposal12 Aug 2026Received
Proposal_2041_accepted.pdfProposal21 Aug 2026Accepted
HACCP-Report_CW36.pdfHACCP report7 Sep 2026Created
Maintenance-Report_AHU-02.pdfInspection report8 Sep 2026Approved
Acceptance_Cold-Room-04.pdfAcceptance15 Jul 2026Completed
Warranty_Booster-Rack.pdfWarranty15 Jul 2026Active

Access by role; every opening is documented in the activity log. Protected BACnet/Modbus files are not visible to customers.

Send a document to JuKo Tech

Demo access: the file stays in your browser and is not transferred. In a customer account it reaches JuKo Tech and appears here with its status.

Categories and statuses — where they come from

  • Categories: The list is fixed and maintained by JuKo Tech in the platform (proposal, order / purchase order, drawing, site plan / photo, HACCP report, inspection report, test report, acceptance, warranty, invoice, other). When uploading, you pick from the part of the list that customers can send; documents the system creates itself – HACCP reports or service-visit reports – get their category automatically.
  • Status: The status follows the life cycle and is set by actions, not by hand: Received – the document was delivered to you · Accepted – you confirmed the proposal in the portal · Created – generated automatically by the system · Approved – checked and released by JuKo Tech · Completed – acceptance declared by you as the client · Active – valid until its expiry date, then automatically “Expired”.

Visits

2 upcoming · 2 completed

Upcoming

  • Condenser cleaning, refrigeration unit 01Production South · from anomaly detection · ticket TK-2026-158
    Scheduled
  • Maintenance, booster rackCentral warehouse North · preventive maintenance
    Scheduled

Completed

  • Maintenance, AHU 02Production South · report filed
    Completed
  • Filter replacement, ventilation unit L1Central warehouse North · invoice filed
    Completed

An on-site contact must be reachable by phone for every visit.

Controls

Demo mode — display only

Demo mode – no physical equipment is controlled. You can switch the systems below on and off, change temperatures and more.
  • Air conditioningServer room Hanau · split AC
    Running
    Set point22.0 °CCan be changed between 18 °C and 26 °C · range read from the controller
  • VentilationProduction South · AHU 02
    Running
  • LightingCentral warehouse North · hall B
    OFF
  • Refrigeration systemProduction South · refrigeration unit 01
    Running
    Set point2.0 °CCan be changed between 0 °C and 8 °C · range read from the controller
    Trigger defrost manually

Set points can only be changed within the range the controller allows – the portal reads the limits from the controller and restricts the input, like a room thermostat. In the demo access the buttons change this display only; no command is sent to any equipment, BMS, BACnet, Modbus or PLC.

Functions by plan

Which functions are available depends on the booked plan.

Functions by plan

Plan
FunctionBasicMaxPro
Client portal
Equipment overview
Documents
Service tickets
HACCP monitoring—
HACCP export (PDF / Excel)—
Alerts—
Activity log—
Remote status—
Trends——
Analytics——
Remote control——

Illustrative mapping — no prices.

Plan your project with us.

We typically reply within one business day.

Request a project